ph.elec
Project Haystack's Xeto specs for electricity
Sum of import and export of the same quantity, such as power, demand, or energy
Max setpoint for AC electric active power demand
Sensor for AC electric active power demand
Sensor for AC electric active energy
Max setpoint for average magnitude of AC electric active power
Sensor for average magnitude of AC electric active power
Sensor for angle of AC electric current
Sensor for angle of AC electric voltage
Sensor for AC electric apparent power demand
Sensor for AC electric apparent energy
Sensor for average magnitude of AC electric apparent power
Sensor for average magnitude of AC electric power
Sensor for AC electric current demand
Max setpoint for RMS of AC electric current
Sensor for AC electric current
Sensor for AC electric demand
Sensor for AC electric energy
Command for AC electric frequency
Sensor for AC electric frequency
Sensor for magnitude of AC electric current
Max setpoint for magnitude of AC electric power
Sensor for magnitude of AC electric voltage
Sensor for AC electric power factor
Sensor for AC electric power demand
Max setpoint for AC electric power
Sensor for metric of AC electric current
Sensor for metric of AC electric voltage
Sensor for AC electric reactive power demand
Sensor for AC electric reactive energy
Sensor for average magnitude of AC electric reactive power
Sensor for RMS of AC electric current
Sensor for RMS of AC electric voltage
Sensor for AC electric voltage
Sensor for instantaneous values of an AC electric current waveform
Sensor for instantaneous values of an AC electric voltage waveform
Active power
Apparent power
Average of an electrical signal over a measurement interval
Command for electricity
Crest Factor
Max setpoint for electric current
Sensor for electric current
Max setpoint for DC electric current
Sensor for DC electric current
Sensor for DC electric energy
Max setpoint for DC electric power
Sensor for DC electric power
Sensor for DC electric state of charge
Sensor for DC electric voltage
Method used to calculate the electric demand to which a value applies
Max setpoint for electric power demand
Sensor for electric demand
Direction of electricity flow to which a value applies
Sensor for electric energy
Even Total Harmonic Distortion (Even THD)
Electricity flowing toward the grid, in the direction of the site meter
Fixed window, also called block interval
Full spectrum
Fundamental
Ground conductor of an AC electric power system
Harmonic
Individual Harmonic Distortion (IHD)
Imbalance
Electricity flowing toward the load
K-Factor
Line 1 (L1) of an AC electric power system
Between line 1 (L1) and line 2 (L2) of an AC electric power system
Line 2 (L2) of an AC electric power system
Between line 2 (L2) and line 3 (L3) of an AC electric power system
Line 3 (L3) of an AC electric power system
Between line 3 (L3) and line 1 (L1) of an AC electric power system
A single line of an AC electric power system
Average of the L1, L2, and L3 values of a three-phase AC electric power system, or the L1 and L2 values of an AC electric power system with two lines
Between two lines of an AC electric power system
Average of the L1-L2, L2-L3, and L3-L1 values of a three-phase AC electric power system
Location within an AC electric power system to which a point's value applies
Calculation used to determine the magnitude of an electrical signal to which a value applies
Max setpoint for electricity
Difference between import and export of the same quantity, such as power, demand, or energy
Neutral conductor of an AC electric power system
Odd Total Harmonic Distortion (Odd THD)
Maximum absolute value of an electrical signal over a measurement interval
Difference between the maximum and minimum values of an electrical signal over a measurement interval
Displacement power factor, which accounts for the phase angle between voltage and current but excludes effects of nonlinear waveforms (harmonic distortion)
Distortion power factor, which measures the component of power factor attributable to harmonic distortion in voltage and current waveforms
Power factor according to the IEC convention defines a positive or negative sign based on the direction of active power flow
Power factor according to the IEEE convention defines a positive or negative sign based on whether the load is capacitive or inductive
Power factor scope
Standard for interpreting power factor's positive or negative sign
True power factor, which includes effects of harmonic distortion
Max setpoint for electric power
AC power quantity to which a value applies
Sensor for electric power
Power quality metric to which a value applies
Reactive power
Root mean square (RMS)
Sensor for electricity
Sliding window, also called rolling interval
Setpoint for electricity
Frequency content of an electrical waveform to which a value applies
Total Harmonic Distortion (THD)
Telephone Harmonic Form Factor (THFF)
Total across all lines of an AC electric power system
Sensor for electric voltage